Products

Aerosol Monitor

 

We are now the proud owners of a top-of-the-line Aerosol Monitor that can be used to evaluate ambient air quality, as well as measure inlet and outlet concentrations from filtration systems. This unit performs equally well at measuring mist, dust, and smoke concentrations, and provides real-time readings as well as logging data. Measurements are taken in mg/m3, and we can set up the system for data cutoff at 10.0, 4.0, 2.5, or 1.0 microns. This can be useful when measuring respirable dust concentrations. Studies can be made by programming the system to run automatically, from minutes to weeks, and the resulting data can be easily plotted to a graph.

Model 8520 DUSTTRAK Aerosol Monitor Specifications:

Sensor type 90 degree light scattering laser photometer
Range 0.001 to 100 mg/m³
Resolution ±0.1% of reading or 0.001 mg/m³, whichever is greater
Zero stability 0.001 mg/m³ over 24 hours using 10 second time constant
Particle size range 0.10 to 10.0 micron
Flow rate Adjustable 1.4 to 2.4 l/min (1.7 nominally)
Data Logging More than 31,000 data points (21 days of logging once/minute)
Logging Interval Adjustable from 1 second to 1 hour
Serial Interface RS-232 1200 baud
Power
AC AC adapter
Battery Four C-size batteries
Battery run-time 16 hours (alkaline batteries)

TRAKPRO Analysis Software Features:

Windows environment (95, 98, Me, NT, 2000)
Program the DUSTTRAK monitor for unattended operation
Download data from the DUSTTRAK monitor
Report generation
Chart generation
Export data in ASCII format

Please allow us to perform your next air quality survey!